83 the alarm system 18, Type of messages, Acknowledging a message – B&G Zeus 12 User Manual
Page 84
83
The Alarm System
18.
Alarms can be set via the Zeus display to indicate warning messages when set
parameters are exceeded, data is unavailable or other general warnings that you wish to
be notified about. When an alarm situation occurs, an alarm message will pop up on the
screen.
Zeus does not relay alarm messages from the H3000 system. Alarms will need to be
setup in Zeus & H3000 with identical parameters if you require both systems to flag
alarm warnings at the same time. It is recommended that core instrument alarms are set
on H3000.
If you have enabled the siren, the alarm message will be followed by an audible alarm.
The alarm is recorded in the alarm listing so that you can see the details and take the
appropriate corrective action.
Type of Messages
The messages are classified according to how the reported situation will affect your
vessel. The following color codes are used:
COLOR
IMPORTANCE
Red
Vital
Orange
Important
Yellow
Standard
Blue
Warning
Green
Light warning
Single alarms
A single alarm is displayed with the name of the alarm as the title, and
with details for the alarm.
Multiple alarms
If more than one alarm is activated simultaneously, the alarm message
will display a list of up to 3 alarms. The alarms are listed in the order
they occur with the alarm activated first at the top. The remaining
alarms are available in the Alarm listing. Refer to The utilities pages
section.
Acknowledging a Message
The following options are available in the alarm dialog for acknowledging a message:
OPTION
RESULT
OK
Sets the alarm state to acknowledged, meaning that you are aware
of the alarm condition. The siren / buzzer will stop and the alarm
dialog will be removed.
The alarm will however remain active in the alarm listing until the
reason for the alarm has been removed.
Disable
Disables the current alarm setting. The alarm will not show again
unless you turn it back on in the Alarm settings dialog.
There is no time-out on the alarm message or siren. These remain until you acknowledge
it or until the reason for the alarm is removed.