1 introduction, 2 specifications – Bio-Rad Whole Gel Eluter and Mini Whole Gel Eluter User Manual

Page 3

Advertising
background image

Section 1
General Information

1.1 Introduction

The Whole Gel Eluter provides an alternative method for recovering samples from SDS

and Native PAGE slab gels. It is a preparative electrophoresis instrument which allows simul-
taneous electro-elution of multiple protein bands separated on a polyacrylamide gel. Elution
is in the transverse direction, through the thickness of the gel. Proteins are eluted into narrow
chambers with each of these fractions containing individual or multiple protein bands.

The eluter consists of a solid acrylic base, a drop-in bottom electrode, an elution cham-

ber core, an upper plate/spring electrode and a lid. The Whole Gel Eluter comes in two sizes.
The large format accommodates slab gels up to 20 cm long and the small format is designed
for mini-gels (Mini-PROTEAN

®

II and Ready Gels). Filter paper and a cellophane sheet are

placed between the bottom electrode and the elution chamber core. The gel is sandwiched
between the top of the elution chamber core and the spring electrode. During elution, the pro-
teins are captured in one of the 30 elution chambers of the large eluter or one of the 14 cham-
bers of the mini eluter.

One important application for this instrument is the purification and subsequent direct

screening of protein mixtures. Andersen and Heron describe a direct cellular analysis of a
complex protein mixture for biological activity.

1

The eluter acts as an electrodialyzer remov-

ing SDS from protein, leaving them in a non-toxic physiological buffer that can then be used
directly in a cellular assay. The Rotofor

®

and Prep cell are recommended for larger scale elec-

trophoretic protein purification.

Simple procedures are provided in this manual for optimizing elution conditions. It is

recommended that these procedures be performed for each new sample and when making
changes to slab gel electrophoresis conditions.

1.2 Specifications

Construction

Base

acrylic/polycarbonate insert

Elution chamber core

acrylic/polycarbonate insert

Bottom electrode

platinum coated titanium plate

Upper plate/spring electrode

acrylic/platinum coated titanium plate

Lid

polycarbonate

Cutting template

acrylic

Consumables

Large

Mini

Upper filter paper

50 sheets

50 sheets

Lower filter paper

75 sheets

50 sheets

Sealing tabs

50 tabs

50 tabs

Cellophane membrane

25 sheets

25 sheets

Other Specifications

Large

Mini

Shipping weight

9.25 lb

4.75 lb

Overall size

5.0” H x 6.0” W x 6.0” D 5.0” H x 10.5” W x 10.5” D

Voltage limit

300 volts

200 volts

Power limit

15 watts

10 watts

Elution sample volume

~3 ml

~0.5 ml

1