Medium-Pressure Column Purification —
Using an Imidazole Gradient to Determine
Optimal Purification of His-Tagged Proteins

Gradient elution tests are useful because they do not require optimization of
imidazole concentrations, but instead may be used to determine suitable imidazole
concentrations for wash and elution steps. Once a suitable concentration has been
determined using a gradient elution such as the one outlined below, often an easier
protocol using step elutions may be used for subsequent purification of larger
sample volumes.

With step elutions, the protein can be collected in smaller volumes and at higher
concentrations. Using this protocol, the concentration of imidazole that elutes the
target protein may be calculated and used for a step protocol.

This protocol requires the use of a gradient mixer coupled to a chromatography
system, such as Bio-Rad’s BioLogic DuoFlow

system, to establish a linear

gradient.

Materials

Reagent

Binding buffer

20 mM sodium phosphate (NaH

2

PO

4

)

300 mM NaCl

20 mM imidazole

Elution buffer

50 mM sodium phosphate (NaH

2

PO

4

)

300 mM NaCl

500 mM imidazole

Equipment

Chromatography system with dual pump and gradient capability

Fraction collector

IMAC column (as prepared in Section 4)

Biological Sample

Clarified lysate (as prepared in Section 7)

Note: Keep the sample as small as possible during optimization of binding and
elution conditions.

Additional Materials

Equipment for assessing protein purity and recovery of the His-tagged
protein