Diagnostic guide – Cleveland Range KEL-25-T User Manual

Page 25

Advertising
background image

Fault Isolation Procedure

Step

Test

1.

Is there proper incoming voltage at
terminal block?

2.

Is the red LED illuminated?

3.

Is the green LED illuminated?

4.

Do both contactors energize?

5.

Measure continuity across safety
thermostat. Is it an open circuit?

6.

Is there 120 VAC present across the
coils of the contactors?

7.

Remove wire from low water level probe
and ground it to the body of the kettle.
Do the contactors now energize?

8.

Is there 16 VAC present at output of 16
VAC transformer?

Result

Remedy

Yes

Go to step #2.

No

Correct external power supply problem.

Yes

Follow Reservoir Fill Procedure. If this
does not correct the problem, go to
Problem D.

No

Go to step #3.

Yes

Go to step #4.

No

Go to step #7.

Yes

Check contactor contacts for pitting. Voltage
across contactor terminals while in a closed
position indicates a poor contact. Replace
contactor/s as necessary. Check elements
for short at ground or an open circuit. If
element/s are defective contact the factory.
Elements are not field replaceable.

No

Go to step #5.

Yes

Replace defective safety thermostat.

No

Go to step #6.

Yes

Replace defective contactor/s.

No

Go to step #6.

Yes

Clean or replace defective low water
level probe. Replace defective red LED.

No

Go to step #8.

Yes

Go to step #9.

No

Replace defective 240/16 VAC transformer.

Possible Causes

1.

No incoming power.

2.

Kettle is tilted.

3.

Low water condition.

4.

Defective ON/OFF switch.

5.

Defective 12 VDC relay.

6.

Defective safety thermostat.

7.

Defective contactor/s.

8.

Defective potentiometer
(temperature control).

9.

Defective low water level
probe.

10.

Defective thermistor.

11.

Defective 240/16 VAC
transformer.

12.

Defective control box.

13.

Defective elements.

DIAGNOSTIC GUIDE

This section contains servicing information intended for use by Authorized Service Personnel.

NOTE 1: If Fault Isolation Procedure is required, be sure to start at step #1.

NOTE 2: On table type kettles the entire control mounting panel may be removed from kettle control
housing for easier troubleshooting and parts replacement.

A/ Problem: Kettle is not heating at all. (Kettle must be on and temperature control set.)

Advertising