GENERAL

Installation of the kettle must be accomplished by
qualified electrical installation personnel working
to all applicable local and national codes.
Improper installation of product could cause injury
or damage.

This equipment is built to comply with applicable
standards for manufacturers. Included among
those approval agencies are: UL, NSF, ASME/Ntl.
Bd., CSA, CGA, ETL, and others. Many local
codes exist, and it is the responsibility of the
owner/installer to comply with these codes.

Note: Maximum voltage for LVD (low volt
directive for Europe) to be 440 volts for CE
marked appliances.

INSPECTION

Before unpacking visually inspect the unit for
evidence of damage during shipping.

If damage is noticed, do not unpack the unit, follow
Shipping Damage Instructions shown below.

SHIPPING DAMAGE
INSTRUCTIONS

If shipping damage to the unit is discovered or
suspected, observe the following guidelines in
preparing a shipping damage claim.

1. Write down a description of the damage or the

reason for suspecting damage as soon as it is
discovered. This will help in filling out the claim
forms later.

2. As soon as damage is discovered or suspected,

notify the carrier that delivered the shipment.

3. Arrange for the carrier's representative to

examine the damage.

4. Fill out all carrier claims forms and have the

examining carrier sign and date each form.

INSTALLATION

The first installation step is to refer to the
Specification Sheets or Specification Drawings for
detailed clearance and drain requirements in
order to determine the location of the kettle. Next,
carefully cut open the shipping carton for easy
removal of the kettle.

CLEARANCE REQUIREMENTS
& RECOMMENDED FLOOR
DRAIN LOCATIONS

INSTALLATION

Model #

A

B

C

D

KEL-25

22 3/8”

34”

5 1/4”

11 1/4”

KEL-30

25 3/8”

37”

6 3/4”

12 3/4”

KEL-40

28 5/8”

40”

7 3/4”

13 3/4”

KEL-40-SH

32 1/2”

44”

9 1/2”

15 1/2”

KEL-60

32 1/2”

44”

9 1/2”

15 1/2”

KEL-80

35 7/8”

47”

11 1/4”

17 1/4”

KEL-100

38 3/8”

50”

12 1/2”

18 1/2”

KEL-25-T

22 1/4”

51 3/4”

4

24”

KEL-40-T

26

56

5 1/2”

28 1/2”

KEL-60-T

29 3/4”

62 1/2”

5 1/2”

31”

KEL-80-T

30 1/2”

65 3/8”

5 1/2”

35 1/2”

KEL-100-T

34 1/8”

69 1/4”

4”

40 1/2”

A

D

C

B

RECOMMENDED
FLOOR DRAIN

2" Tangent

Draw-Off

Valve

RECOMMENDED

FLOOR DRAIN

RECOMMENDED

FLOOR DRAIN

A

D

C

B

RECOMMENDED
FLOOR DRAIN

RECOMMENDED

FLOOR DRAIN

12" x 12"

2" Tangent

Draw-Off

Valve

Clearance Requirements

Back

Left Side

Right Side *

0

0

12'

*

Minimum recommended
clearance for service

**

Above dimensions apply to standard 2" Tangent Draw-Off Valve
only. For other valves consult factory.

Recommended Floor Drain Locations **

Tilting

Models

Stationary

Models