Recommended floor drain detail assembly, Wire connection, Water – Cleveland Range KEL-25-T User Manual

Page 4

Advertising
background image

RECOMMENDED FLOOR
DRAIN DETAIL

ASSEMBLY

Position the kettle in it's permanent location, and
level the kettle by turning the adjustable flanged
feet. Once positioned and leveled, permanently
secure the kettle's flanged feet to the floor using
5/16" lag bolts and floor anchors (supplied by the
installer). There are three bolts required to secure
each of the flanged feet.

WIRE CONNECTION

Install in accordance with local codes and/or the
National Electric Code ANSI/NFPA No. 70-1990
(USA) or the Canadian Electric Code CSA
Standard C22.1 (Canada). A separate fused
disconnect switch must be supplied and installed.
The kettle must be electrically grounded by the
installer.

The electrical supply must match the power
requirements specified on the kettle's rating plate.
The copper wiring must be adequate to carry the
required current at the rated voltage.

Note: Maximum voltage for LVD (low voltage
directive for Europe) to be 440 volts for CE
marked appliances.

The kettle is wired for 3-phase operation at the
factory. For single phase operation, rewire the
terminal block to that shown in the above diagram.

Note: Ensure main power is turned off before
connecting wires.

Stationary Models

Remove the screws securing the dome-shaped
service cover underneath the kettle and remove
the cover. A wiring diagram is affixed to the inside
of cover. Fasten permanent copper wiring to the
three-connection terminal block, Be sure to
connect ground wire to the separate ground
terminal connector (ground lug). Slide the cover's
slot over the wiring and secure the cover to kettle
with the screws.

Tilting Models

First remove the handwheel by loosening the allen
screw. Then remove the two screws at the front
and rear of the console cover and remove the
cover. A wiring diagram is affixed to the underside
of the console cover. Feed permanent copper
wiring through the cut-out in the bottom of the
console, and fasten to the three-connection
terminal block. Be sure to connect the ground
terminal connector (ground lug). Replace the
console cover and handwheel.

WATER

The sealed jacket of the electric kettle is
precharged with the correct amount of a water-
based formula, and therefore, no water connection
is required to the kettle jacket. The kettle can be
equipped with optional hot and cold water taps,
the taps require 1/2" copper tubing as supply
lines.

RED
YELLOW
BLACK

BLACK

BLUE

RED

L1 L2 L3

THREE
PHASE

RED
YELLOW
BLACK

BLACK

BLUE

RED

L1

L2

SINGLE
PHASE

4" MINIMUM,
6" RECOMMENDED

PIPE DRAIN
RECOMMENDED

MINIMUM VALVE
SIZE PLUS 1"

FLOOR SLOPE
1" IN 4'

RECOMMENDED
FLOOR
DRAIN

(3) 7/16" DIA.
HOLES

FLANGED
FOOT
(5" DIA)

3 1/8"

Flanged Foot Detail