OPERATING INSTRUCTIONS

General Parts Drawing

ITEM #

DESCRIPTION

FUNCTION

1.

On-Off Switch/Solid State

Turns kettle ON/OFF and allows the operator to adjust the kettle

Temperature Control

temperature in increments from 1 (Min.) to 10 (Max.).
(see Temperature Range Chart in the Operating Instructions
section).

2.

Heat Indicator Light (Green)

When lit, indicates that the kettle element is on.
Cycles ON-OFF with element.

3.

Low Water Indicator Light (Red)

When lit, indicates that the kettle is low on water and will not operate
in this condition. This will also light when the kettle is tilted.

4.

Vacuum/Pressure Gauge

Indicate steam pressure in PSI inside steam jacket as well as
vacuum in inches of mercury.

5.

Pressure Relief Valve

This valve is used to vent the kettle and in the unlikely event there is

(not shown)

an excess steam build-up in the jacket, this valve opens
automatically to relieve this pressure.

6.

Tilt Wheel

Used for tilting the kettle up or down. Some units have an optional
Power Tilt Control Switch located in the same position.

7.

Power Tilt Control Switch

Used for tilting the kettle up or down.

(not shown)

8.

Tangent Draw-Off Valve

Used for draining product or wash water from kettle. It is supplied as

standard equipment on stationary kettles and is optional on tilting kettles.