For the ROM Write of the parameter, a reply with data has been sent by all means by a controller.
The content of data is different by a parameter. (For details, see 7-3, “Parameter Details.”)

Note Please make the ROM write of the parameter after enough confirmation. Depending on

value for change, the controller may not start normally.

Parameter ROM Write send

E Axis

No. P Command ID / Data Delimiter

E.g. LQ gain parameter ID = 6 Data = 4500

E1P006 / 4500 (LF)

(ASCII code: 0x45 0x31 0x50 0x30 0x30 0x36 0x2f 0x34 0x35 0x30 0x30 0x0a)

E 1 P 0 0 6 / 4 5 0 0 (LF)

Parameter ROM Write reply

E Axis

No. P Command ID / Data Delimiter

E.g. LQ gain parameter ID = 6 Data = 4500

E1P006 / 4500 (LF)

(ASCII code: 0x45 0x31 0x50 0x30 0x30 0x36 0x2f 0x30 0x0a)

E 1 P 0 0 6 / 0 (LF)

Axis No.

1 or 2

Command ID
Decimal, 3-digit
(See 7-1 for details)

Parameter setting

Decimal

Parameter

Delimiter

LF or CR

Axis No.

1 or 2

Command ID
Decimal, 3-digit
(See 7-1 for details)

Parameter setting

successful / unsuccessful

0 or 1

Parameter

Delimiter

LF or CR