CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

68

Parameter ID

7

Parameter

Name

Torque Constant

Data

Torque constant (Unit: gf cm / A)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the torque constant of the motor.

Note: Do not change this parameter. A unique value is available depending on the
motor model. This is set at shipping.

Related
Command
/Parameter

LQ control related parameters
LQ Control Gain (Parameter ID = 6)
Total Inertia (Parameter ID = 8)

Parameter ID

8

Parameter

Name

Total Inertia

Data

Total inertia (Unit: 0.01 gf cm

2

)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the inertia due to the motor rotation shaft and the mirror.

Note: Be careful about the unit. Set a value of gf cm

2

multiplied by 100.

Related
Command
/Parameter

LQ control related parameters:
LQ Control Gain (Parameter ID = 6)
Torque Constant (Parameter ID = 8)

Parameter ID

9

Parameter

Name

Current Limit

Data

Current limit (Unit: %)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the upper limit of a current command value. (Setting for
each axis as a ratio to 10A)
E.g.: 90% (10A × 0.9 = 9A)
If the current remains over the upper limit for a specified time, a current saturation error
occurs.

Related
Command
/Parameter

Bit 5 “Current Saturation” becomes 1 in error read (Command ID = 15).