Canon GALVANO GC-251 User Manual

Page 61

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

61

Command ID

41

Command

Name

Monitor Output Selection (A3, A9)

Data

0: Position
1: Velocity
2: Course Angle
3: Fine Angle

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

The output signal of analog monitor output A3 (the Axis1) and A9 (the Axis2) can be
selected.
When the controller starts, the 1: Velocity has been selected.
(For details, see 5.2, “Analog Monitor Output Selecting ”)

Related
Command

Command ID = 45: Monitor Magnification Setting (A3, A9 )

Command ID

42

Command

Name

Monitor Output Selection (A4, A10)

Data

0: Encoder Head1 B phase
1: Encoder Head2 B phase
2: Corrected B phase
3: Internal Target

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

The output signal of analog monitor output A4 (the Axis1) and A10 (the Axis2) can be
selected.
When the controller starts, the 3: Internal Target has been selected.
(For details, see 5.2, “Analog Monitor Output Selecting ”)

Related
Command

Command ID = 46: Monitor Magnification Setting (A4, A10 )

Command ID

43

Command

Name

Monitor Output Select Check

Data

0: A2, A8 monitor
1: A3, A9 monitor
2: A4, A10 monitor

Return
Value

0: Command execution successful
1: Command execution unsuccessful

Explanation

The number of the monitor signal that has been selected by command ID=40, 41, and 4
2 can be confirmed.
E.g. A1C040/0

Return Value = 3 (Axis1 monitor A2 = Position error)

Related
Command





Advertising