Parameter ID

64

Parameter

Name

DSP Operation Setting

Data

DSP operation setting (Unit: none)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is used to set the activation mode. Each bit has a meaning.

Bit 0 0: No automatic encoder correction at homing to the origin
1: Automatic encoder correction at homing to the origin

Bit 1 0: Activation in internal clock mode
1: Activation in high-speed serial communication (external clock) mode

Bit 2 0: High-speed serial communication specification (XY2-100) (Usually 0)


Note: The setting is decimal.

Related
Command
/Parameter

Parameter ID

66

Parameter

Name

High Speed Serial Status Format

Data

High Speed Serial Status Format (Unit: none)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

The content of status output to the status line of high-speed serial communications can
be selected.
1

Controller Condition

2

Current position (Axis 1)

3

Current position(Axis 2)

4

Current position(Axis1 , Axis2)

(For details, see 2.7.2, “High Speed Serial Communications”)

Related
Command
/Parameter

Parameter ID

67

Parameter

Name

High Speed Serial Data Length

Data

High Speed Serial Data Length (Unit: bit) Range = 16 20

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

Position Data length of High speed serial communication can be specified.
Range = 16bit

20bit

(For details, see 2.7.2, “High Speed Serial Communications”)

Related
Command
/Parameter