Canon GALVANO GC-251 User Manual

Page 70

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

70

Parameter ID

13

Parameter

Name

High-speed Serial Communication
Conversion Gain

Data

High-speed serial communication conversion gain (Unit: Multiple × 1000)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

High-speed serial communication data is specified by 16 bits.
Ordinary data is 1 for one pulse and can be specified up to the following positions:

Maximum position: 0xFFFF = 32767 pulses = About 5.76 deg (GM-1010)
0-pulse position: 0x8000 = 0
Minimum position: 0x0000 = –32768 pulses = About –5.76 deg (GM-1010)

If a greater angle is specified, set a magnification by using the high-speed serial

communication conversion gain (Parameter ID = 13).
E.g. For x2 (Setting: 2000), the following angle can be specified:
–5.76×2 deg to –5.76×2 deg
The command resolution will be two times.

Related
Command
/Parameter

Parameter ID

14

Parameter

Name

Origin Clearance Timing (Head 2)

Data

Origin clearance timing (0 or 1)

Return Value

0: Parameter setting successful
1: Parameter setting unsuccessful

Explanation

This parameter is related to origin detection.
The value checked by “Command ID = 101: Counter Clear Timing” is set.
Each motor has a unique value (0 or 1).

Note: An appropriate value is set at shipping. When only the motor is replaced, the
value should be checked and set by a command.
The Origin Clearance Timing (Head 1) parameter should be set at the same time.

Related
Command
/Parameter

Counter Clear Timing (Command ID = 101)
A1C101/ 1 (Axis 1 Head 2)
Set the value checked above.