Dell PowerVault MD3820f User Manual

Page 216

Advertising
background image

3. To locate the directory in which the file to download resides, click Select File next to the Selected

RAID controller module firmware file text box.

4. In the File Selection area, select the file to download.

By default, only the downloadable files that are compatible with the current storage array
configuration are displayed.
When you select a file in the File Selection area of the dialog, applicable attributes (if any) of the file
are displayed in the File Information area. The attributes indicate the version of the file.

5. If you want to download an NVSRAM file with the firmware:

a) Select Transfer NVSRAM file with RAID controller module firmware.
b) Click Select File.

6. To transfer the files to the RAID controller module without activating them, click Transfer files but

don't activate them (activate later).

7. Click Transfer.

Keep these guidelines in mind:

– If the Transfer button is inactive, ensure that you either select an NVSRAM file or clear the

Transfer NVSRAM file with RAID controller module firmware check box.

– If the file selected is not valid or is not compatible with the current storage array configuration,

the File Selection Error dialog is displayed. Click OK to close it, and choose a compatible

firmware or NVSRAM file.

8. In the Confirm Download dialog, click Yes.

The download starts.

9. If you are using the EMW, perform one of these actions:

– Select Tools → Upgrade RAID Controller Module Firmware.
– Select the Setup tab, and click Upgrade RAID Controller Module Firmware.

10. In the Storage array pane, select the storage array for which you want to upgrade the RAID

controller module firmware or the NVSRAM.
You can select more than one storage array.

NOTE: The Details pane shows the details of only one storage array at a time. If you select more
than one storage array in the Storage Array pane, the details of the storage arrays are not shown
in the Details pane.

11. Click Firmware in the Download area.

If you select a storage array that cannot be upgraded, the Firmware button is disabled. The
Download Firmware dialog is displayed. The current firmware version and the NVSRAM version of
the selected storage arrays appear.

NOTE: If you select the storage arrays with different RAID controller module types that cannot
be updated with the same firmware or NVSRAM file and click Firmware, the Incompatible RAID
Controller Modules dialog is displayed. Click OK to close the dialog and select the storage
arrays with similar RAID controller module types.

12. To locate the directory in which the file to download resides, click Browse in the Select files area.

The Select File dialog is displayed.

13. Select the file to download.
14. Click OK.

216

Advertising