System board connectors, Scsi backplane board connectors, Disabling a forgotten password – Dell PowerEdge 1650 User Manual

Page 3: Table a, For the designations, default settings, and

Advertising
background image

 

System Board Connectors

See

Figure 6

-1

and

Table 6

-1

for the location and description of system board connectors.

SCSI Backplane Board Connectors

Figure A

-3

shows the location of the connectors on the top of the SCSI backplane board.

Figure A-3. Connectors on the SCSI Backplane Board

 

 

Disabling a Forgotten Password

The system's software security features include a system password and a setup password, which are discussed in detail in "Using the System Setup Program"
in the User's Guide. A password jumper on the system board enables these password features or disables them and clears any password(s) currently in use.

To disable a forgotten system password or setup password, perform the following steps.

1.

 

Open the system doors (see "

Opening the System Doors

" in "Troubleshooting Your System").

2.

 

Refer to

Figure A

-2

for the location of the password jumper (labeled "PASSWD") on the system board.

3.

 

Remove the jumper plug from the PASSWD jumper.

4.

 

Replace the system cover, and then reconnect the system to an electrical outlet and turn it on.

The existing passwords are not disabled (erased) until the system boots with the PASSWD jumper plug removed. However, before you assign a new
system and/or setup password, you must install the jumper plug.

5.

 

Repeat step 1.

Table A-1. System-Board Jumper Settings 

Jumper

Setting

Description

PASSWD

(default) The password feature is enabled.

The password feature is disabled.

NVRAM_CLR

(default) The configuration settings are retained at system boot.

The configuration settings are cleared at next system boot. (If the configuration settings become corrupted to the point
where the system will not boot, install the jumper plug and boot the system. Remove the jumper before restoring the
configuration information.)

RSVD

Reserved (do not change).

jumpered  

unjumpered

NOTE:

For the full name of an abbreviation or acronym used in this table, see "

Abbreviations and Acronyms

."

CAUTION:

See "Protecting Against Electrostatic Discharge" in the Safety Instructions in your System Information document.

NOTE:

If you assign a new system and/or setup password with the jumper plug still removed, the system disables the new password(s) the next

time it boots.