Chapter 8. Error codes

If an error occurs during operation of the library, the library stops the current
operation and displays an error code on the LCD screen. Unless otherwise noted in
“Error codes” on page 8-2, try to resolve the error by cycling power to the library
and retrying the last operation. If the error persists, contact technical support.

Example error code

EVENT -6

8D 07

Where:

v

-6

indicates the position in sequence list, 0 being the most recent.

v

8D 07 indicates the error. (code 8D = sled blocked,).

The event log with the library also includes a date stamp for each event. Press
SELECT to display the associated time stamp in the following format:

yy.mm.dd hh:mm:ss:HH

Where:

v

yy

is the year

v

mm

is the month

v

dd

is the current day

v

hh

is hours

v

mm

is minutes

v

ss

is seconds

v

HH

is 1/100 second

The time stamp is set to zero at system start.

A description of each error code and possible solution is provided in “Error codes”
on page 8-2.

Preparing to resolve an error code

1.

Record the error information that is displayed on the Operator Control Panel
display or Web User Interface screen.

2.

If possible, cycle library power and retry the operation.

v

If the error recurs, refer to “Error codes” on page 8-2 for information about
resolving the error.

v

If the error does not recur, run Library Verify before normal library operation
is continued.

Complete the steps in “Preparing to resolve an error code” before you complete
the User Action listed in “Error codes” on page 8-2.