VMware Supervisors Prerequisites

The virtualization module requires the following prerequisites:

• VMware vCenter and VMware vSphere Client must be installed.

NOTE:

vCenter and Dell MUMC could be installed on the same server (or on a VM/Server on the network)

• To provide the VM graceful shutdown, you have to install VMware tools on each VM.
• You must also have a knowledge / experience with Dell MUMC software and VMware infrastructure.

NOTE:

Since Dell MUMC Release 2 (Version 01.04), the VMware vSphere Software Development Kit (SDK) for Perl is no

longer required.

Microsoft Supervisors Prerequisites

The virtualization module needs following prerequisites:

• The Powershell Snapin for Microsoft SCVMM. Either install the VMM console on the machine

hosting Dell MUMC, or install Dell MUMC on the machine hosting SCVMM.

• The server hosting Dell MUMC must be on the same Windows Domain than SCVMM Server
• The server hosting Dell MUMC must enable the execution of third party scripts on the local machine

(minimum access “Remote Signed,” for example: Set-ExecutionPolicy RemoteSigned).

Figure 68 displays the parameters after the configuration example:

Figure 68. Windows PowerShell - Virtual Machine Manager

0119_2-Dell MUMC UG.book Page 89 Saturday, November 2, 2013 4:59 PM