Dell PowerVault DX6104 User Manual

Page 13

Advertising
background image

Hard-drive indicator

Condition

Corrective Action

The indicator lights
green to indicate
hard-drive activity.

None required.

Electrical indicator

Condition

Corrective Action

The indicator blinks
amber if the system
experiences an
electrical error (for
example, voltage out
of range, or a failed
power supply or
voltage regulator).

See the System Event Log or system messages for the specific issue.
If it is due to a problem with the power supply, check the LED on the
power supply. Re-seat the power supply by removing and reinstalling
it. If the problem persists, see

Getting Help

.

Temperature indicator

Condition

Corrective Action

The indicator blinks
amber if the system
experiences a
thermal error (for
example, a
temperature out of
range or fan failure).

Ensure that none of the following conditions exist:

A cooling fan is removed or has failed.

System cover, cooling shroud, EMI filler panel, memory-

module blank, or back-filler bracket is removed.

Ambient temperature is too high.

External airflow is obstructed.

See

Getting Help

.

Memory indicator

Condition

Corrective Action

The indicator blinks
amber if a memory
error occurs.

See the system event log or system messages for the location of the
failed memory. Reinstall the memory device. If the problem persists,
see

Getting Help

.

13

Advertising