Removing a cooling fan – Dell PowerVault DX6104 User Manual

Page 52

Advertising
background image

NOTE: Hot-swap removal or installation of the fans is not supported.

NOTE: In the event of a problem with a particular fan, the fan number is referenced by the system’s management
software, allowing you to easily identify and replace the proper fan by noting the fan numbers on the cooling fan
assembly.

Removing A Cooling Fan

WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric
shock. Exercise utmost care while removing or installing cooling fans.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.

CAUTION: Do not operate the system with the cover removed for a duration exceeding five minutes.

NOTE: The procedure for removing each fan is identical.

1.

Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.

2.

Open the system.

3.

Remove the cooling shroud or power distribution board shroud as applicable.

4.

Disconnect the fan's power cable from the power cable connector on the system board or power distribution board

as applicable.

5.

Lift the fan out of the cooling-fan bracket.

Figure 17. Removing A Cooling Fan