Dell POWEREDGE R610 User Manual

Page 26

Advertising
background image

26

About Your System

E1311

Fan module ##

RPM exceeding

range. Check

fan.

RPM of specified fan in

specified module is outside

of intended operating

range.

See "Troubleshooting

System Cooling

Problems."

E1313

Fan

redundancy

lost. Check

fans.

The system is no longer fan

redundant. Another fan

failure would put the

system at risk of over-

heating.

Check LCD for additional

scrolling messages. See

"Troubleshooting a Fan."

E1410

System Fatal

Error

detected.

A fatal system error has

been detected.

Check LCD for additional

scrolling messages.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help."

E1414

CPU # temp

exceeding

range. Check

CPU heatsink.

Specified processor is out of

acceptable temperature

range.

Ensure that the processor

heat sinks are properly

installed. See

"Troubleshooting the

Processors" and

"Troubleshooting System

Cooling Problems."

E1418

CPU # not

detected.

Check CPU is

seated

properly.

Specified processor is

missing or bad, and the

system is in an unsupported

configuration.

Ensure that the specified

microprocessor is properly

installed. See

"Troubleshooting the

Processors."

E141C

Unsupported

CPU

configuration

Check CPU or

BIOS

revision.

Processors are in an

unsupported configuration.

Ensure that your

microprocessors match

and conform to the type

described in the

microprocessor technical

specifications outlined in

your system’s Getting

Started Guide.

Table 1-1. LCD Status Messages

(continued)

Code

Text

Cause

Corrective Actions