38

About Your System

Alert! iDRAC6 not

responding.

Rebooting.

The iDRAC6 is not

responding to BIOS

communication either

because it is not functioning

properly or has not

completed initialization. The

system will reboot.

Wait for the system to

reboot.

Alert! iDRAC6 not

responding.

Power required

may exceed PSU

wattage.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The iDRAC6 is not

responding.
The iDRAC6 was remotely

reset while system was

booting
After AC recovery, the

iDRAC6 takes longer than

normal to boot.

Remove AC power to the

system for 10 seconds and

restart the system.

Alert! Node

Interleaving

disabled! Memory

configuration

does not support

Node

Interleaving.

The memory configuration

does not support node

interleaving, or the

configuration has changed

(for example, a DIMM has

failed) so that node

interleaving cannot be

supported.

The system will

run but node interleaving will

be disabled.

Ensure that the memory

modules are installed in a

configuration that supports

node interleaving. Check

other system messages for

additional information for

possible causes. For memory

configuration information,

see "System Memory." If the

problem persists, see

"Troubleshooting System

Memory."

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions