Dell POWEREDGE R610 User Manual

Page 42

Advertising
background image

42

About Your System

Embedded NIC

x

and

NIC

y

:

OS NIC=DISABLED,

Management

Shared NIC=

DISABLED

The OS NIC interface is

disabled in BIOS. The

Management Shared NIC

interface is disabled in

management tools.

Check the system

management software or the

System Setup program for

NIC settings. If a problem is

indicated, see

"Troubleshooting a NIC."

Embedded NIC

x

and

NIC

y

:

OS NIC=DISABLED,

Management

Shared NIC=

ENABLED

The OS NIC interface is

disabled in BIOS. The

Management Shared NIC

interface is enabled in

management tools.

Check the system

management software or the

System Setup program for

NIC settings. If a problem is

indicated, see

"Troubleshooting a NIC."

Error 8602 -

Auxiliary Device

Failure. Verify

that mouse and

keyboard are

securely

attached to

correct

connectors.

Mouse or keyboard cable is

loose or improperly

connected.

Reseat the mouse or

keyboard cable.

Defective mouse or keyboard. Ensure that the mouse or

keyboard is operational. See

"Troubleshooting a USB

Device."

Gate A20 failure

Faulty keyboard controller;

faulty system board.

See "Getting Help."

General failure

The operating system is

unable to carry out the

command.

This message is usually

followed by specific

information. Note the

information, and take the

appropriate action to resolve

the problem.

Invalid

configuration

information -

please run SETUP

program.

An invalid system

configuration caused a

system halt.

Run the System Setup

program and review the

current settings. See "Using

the System Setup Program

and UEFI Boot Manager."

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions

Advertising