Installing memory modules – Dell PowerEdge C6100 User Manual

Page 80

Advertising
background image

80

Installing System Components

5 Press down and out on the ejectors on each end of the socket until the

memory module pops out of the socket. See Figure 3-16.

Handle each memory module only on either card edge, making sure not
to touch the middle of the memory module.

6 Replace the cooling shroud. See "Installing the Cooling Shroud" on

page 64.

7 Replace the system-board assembly. See "Installing a System-Board

Assembly" on page 62.

Reconnect the system to the electrical outlet and turn the system on, including
any attached peripherals.

Installing Memory Modules

WARNING:

The memory modules are hot to the touch for some time after the

system has been powered down. Allow time for the memory modules to cool
before handling them. Handle the memory modules by the card edges and avoid
touching the components on the memory module.

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.

1 Turn off the system, including any attached peripherals, and disconnect

the system from its electrical outlet.

2 Remove the system-board assembly. See "Removing a System-Board

Assembly" on page 61.

3 Remove the cooling shroud. See "Removing the Cooling Shroud" on

page 63.

4 Locate the memory module sockets. See Figure 3-15.
5 Press the ejectors on the memory module socket down and out, as shown

in Figure 3-16, to allow the memory module to be inserted into the socket.

6 Handle each memory module only on either card edge, making sure not to

touch the middle of the memory module.