Backplane, Installing the fan module, Removing the backplane – Dell PowerEdge C2100 User Manual

Page 102

Advertising
background image

98

Installing System Components

Installing the Fan Module

NOTE:

Note the direction of airflow on the fan modules and ensure that the fan

modules are oriented in the correct direction while installing.

Align the slots on the fan module with the slots on the fan assembly such that

the labelled side faces the back of the system. Secure the fan module to the

fan assembly using the screws. See Figure 3-23.

Backplane

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.

Removing the Backplane

1 Turn off the system, including any attached peripherals, and disconnect

the system from its electrical outlet.

2 Open the system. See "Opening the System" on page 58.
3 Remove the cooling fan assembly. See "Removing a Cooling Fan Assembly"

on page 95.

4 Disconnect the SAS/SATA cables, the fan cables, and the power cables

from the backplane. See Figure 5-4.

CAUTION:

To prevent damage to the drives and backplane, you must remove the

hard drives from the system before removing the backplane.

CAUTION:

You must note the number of each hard drive and temporarily label

them before removal so that you can replace them in the same locations.

5 Remove all the hard drives. See "Removing a Hard-Drive Carrier" on

page 54.

6 Remove the three screws that secure the backplane to the system. See

Figure 3-24.

7 Slide the backplane and lift it clear off the system.

book.book Page 98 Friday, November 8, 2013 11:29 AM