Removing the expansion card – Dell PowerEdge C2100 User Manual

Page 82

Advertising
background image

78

Installing System Components

5 Replace the system cover. See "Closing the System" on page 59.
6 Reconnect the system and peripherals to their electrical outlets, and turn

on the system.

Removing the Expansion Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.

1 Turn off the system, including any attached peripherals, and disconnect

the system from its electrical outlet.

2 Open the system. See "Opening the System" on page 58.
3 Remove the cooling shroud. See "Removing the Cooling Shroud" on

page 60.

4 Remove the expansion-card riser. See "Removing the Expansion-Card

Riser" on page 75.

5 Remove the screw that secures the expansion card to the expansion-card

riser assembly. See Figure 3-14.

6 Pull out the expansion card from the expansion-card riser. See Figure 3-14.

CAUTION:

Disconnecting the RAID battery cable from a PERC card can cause

data loss if the "dirty cache" LED on the card is lit. The LED indicates that data is
still cached in controller memory and the data was not cleared at system
shutdown. Remove the RAID controller and raid battery as a set when the LED is
lit.

7 If removing a PERC RAID controller card, disconnect the RAID battery

cable from the expansion card.

NOTE:

You must install a filler bracket over an empty expansion slot to

maintain Federal Communications Commission (FCC) certification of the

system. The brackets also keep dust and dirt out of the system and aid in

proper cooling and airflow inside the system.

8 Insert the filler bracket.