Back-panel indicators and features – Dell PowerVault MD3000 User Manual

Page 13

Advertising
background image

About Your System

13

Back-Panel Indicators and Features

Figure 1-4 shows the back-panel features of the enclosure. Two RAID controller modules and two power
supply/cooling fan modules must be installed for the enclosure to operate properly. However, the
enclosure can run temporarily on one power supply/cooling fan module. For more information, see
"Power Supply and Cooling Fan Features" on page 18.

Figure 1-4.

Back-Panel Features

Green flashing (250 milliseconds
[ms])

Physical disk is being identified

Green flashing
On 400 ms
Off 100 ms

Physical disk rebuilding

Amber flashing (125 ms)

Physical disk failed

Flashing green, amber, and off

Physical disk failure predicted (SMART)

Green 3 seconds, amber
3 seconds, and off 3 seconds

Physical disk rebuild aborted

1

RAID controller module 0

2

RAID controller module 1

3

power supply/cooling fan
modules (2)

Table 1-3.

Physical Disk Carrier Status LEDs (continued)

Status LED

Description

1

2

3

Advertising