Removing and installing the midplane – Dell PowerVault MD3000 User Manual

Page 66

Advertising
background image

66

Installing Enclosure Components

6 Reconnect power cables to the enclosure and power it back on.
7 Power on the host server.

Removing and Installing the Midplane

CAUTION:

Only trained service technicians are authorized to remove the enclosure cover and access any of the

components inside the enclosure. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the enclosure and protecting against
electrostatic discharge.

The enclosure midplane contains the connectors for the physical disks, RAID controller module, control
panel, and power supply/cooling modules.

1 Complete the "Removing the Control Panel" on page 64 steps as shown in "Removing and Installing

the Control Panel" on page 64.

2 Remove the RAID controller modules from the enclosure. (See "Removing and Installing a RAID

Controller Module" on page 59.)

3 Remove both power supply/cooling modules from the enclosure. (See "Removing and Installing the

Power Supply/Cooling Fan Module" on page 62.)

4 Remove the four Phillips screws holding the controller/power supply cage in the enclosure (see

Figure 4-8).

Advertising