Cabling Your RAID Enclosure

21

Cabling Your RAID Enclosure

This section provides the following information:

Procedures for connecting your RAID enclosure to a host system

A description of redundant, nonredundant, and clustering configurations, including cabling
diagrams for each

Before You Begin

Before connecting your RAID enclosure, ensure that the following are available:

The components that shipped with your RAID enclosure, including:

Power cords (2)

SAS interconnect cables

MD3000 Resource CD

Rail kit

Any relevant documentation, including:

Getting Started Guide

Rack Installation Guide or Rack Installation Instructions

Product Information Guide (for important safety, regulatory, and warranty information)

Readme files

#2 Phillips screwdriver

About the Enclosure Connections

The RAID array enclosure is connected to a host via two hot-pluggable RAID controller modules.
The RAID controller modules are identified as RAID controller module 0 and RAID controller
module 1 (see Figure 1-4).

Each RAID controller module has at least one SAS In port connector that provides the direct
connection to the host or node. A second SAS In port connector is available on the optional dual-
port RAID controller. SAS In port connectors are labeled In-0 and, if using the optional controller,
In-1(see Figure 1-5).

NOTE:

When you cable from a host server to an MD3000 SAS In port connector, either Out port of the server’s

HBA can be used.