Dell PowerVault MD3000 User Manual

Page 73

Advertising
background image

Troubleshooting Your Enclosure

73

NOTICE:

This procedure can destroy data stored on the physical disks. Before you continue, back up all files on

the disk.

Problem

A single physical disk is not seen in MD Storage Manager.

Action

1 Remove the physical disk from the enclosure. See "Removing and Installing Physical Disks" on

page 56.

2 Inspect the physical disk and midplane connectors for obvious damage.
3 Re-install the physical disk in its original bay. See "Removing and Installing Physical Disks" on page 56.

If the problem persists, see "Getting Help" on page 77.

Problem

Physical disk status LED is flashing amber.

Action

1 Review MD Storage Manager for possible recovery actions.

NOTE:

If a physical disk rebuild is under way, allow the rebuild to complete.

2 Remove the physical disk from the enclosure. See "Removing and Installing Physical Disks" on

page 56.

3 Inspect the disk and midplane connectors for obvious damage.
4 Re-install the disk in its original bay. See "Removing and Installing Physical Disks" on page 56.

If the problem persists, see "Getting Help" on page 77.

Problem

Multiple physical disks are not seen in MD Storage Manager.

Action

1 Make sure that all cables are attached correctly according to the enclosure mode you selected. For more

information on enclosure modes, see "Cabling Your RAID Enclosure" on page 21.

2 Verify that the SAS port link status LED is solid green for each port that is connected to a cable. If it is

not, see "Back-Panel Indicators and Features" on page 13.

3 If you reseated cables, reboot the host server.

If the problem persists, see "Getting Help" on page 77.

Advertising