Dell PowerVault MD3000 User Manual

Page 73

Advertising
background image

Troubleshooting Your Enclosure

73

NOTICE:

This procedure can destroy data stored on the physical disks. Before you continue, back up all files on

the disk.

Problem

•

A single physical disk is not seen in MD Storage Manager.

Action

1 Remove the physical disk from the enclosure. See "Removing and Installing Physical Disks" on

page 56.

2 Inspect the physical disk and midplane connectors for obvious damage.
3 Re-install the physical disk in its original bay. See "Removing and Installing Physical Disks" on page 56.

If the problem persists, see "Getting Help" on page 77.

Problem

•

Physical disk status LED is flashing amber.

Action

1 Review MD Storage Manager for possible recovery actions.

NOTE:

If a physical disk rebuild is under way, allow the rebuild to complete.

2 Remove the physical disk from the enclosure. See "Removing and Installing Physical Disks" on

page 56.

3 Inspect the disk and midplane connectors for obvious damage.
4 Re-install the disk in its original bay. See "Removing and Installing Physical Disks" on page 56.

If the problem persists, see "Getting Help" on page 77.

Problem

•

Multiple physical disks are not seen in MD Storage Manager.

Action

1 Make sure that all cables are attached correctly according to the enclosure mode you selected. For more

information on enclosure modes, see "Cabling Your RAID Enclosure" on page 21.

2 Verify that the SAS port link status LED is solid green for each port that is connected to a cable. If it is

not, see "Back-Panel Indicators and Features" on page 13.

3 If you reseated cables, reboot the host server.

If the problem persists, see "Getting Help" on page 77.

Advertising