Dell PowerEdge T110 II User Manual

Page 21

Advertising
background image

About Your System

21

Caution!

NVRAM_CLR jumper

is installed on

system

board.Please run

SETUP.

NVRAM_CLR jumper is

installed in the clear

setting. CMOS has been

cleared.

Move the NVRAM_CLR

jumper to the default position

(pins 3 and 5). See Figure 6-1

for jumper location. Restart

the system and re-enter the

BIOS settings. See "Using the

System Setup Program and

UEFI Boot Manager" on

page 35.

CPU set to

minimum

frequency.

The processor speed may

be intentionally set lower

for power conservation.

If not an intentional setting,

check other system messages

for possible causes.

Current boot mode

is set to UEFI.

Please ensure

compatible

bootable media is

available. Use

the system setup

program to change

the boot mode as

needed.

The system failed to boot

because UEFI boot mode is

enabled in BIOS and the

boot operating system is

non-UEFI.

Ensure that the boot mode is

set correctly and that the

proper bootable media is

available. See "Using the

System Setup Program and

UEFI Boot Manager" on

page 35.

Decreasing

available

memory.

Faulty or improperly

installed memory modules.

Reseat the memory modules.

See "Troubleshooting System

Memory" on page 119.

Embedded NICx and

NICy:

OS NIC=<ENABLED

|DISABLED>,

Management

Shared NIC=

<ENABLED

|DISABLED>

The operating system NIC

interface is set in BIOS.

The Management Shared

NIC interface is set in

management tools.

Check the system

management software or the

System Setup program for

NIC settings. If a problem is

indicated, see

"Troubleshooting a NIC" on

page 113.

Message

Causes

Corrective Actions

Coaster_HOM.book Page 21 Monday, November 3, 2014 3:23 PM