Unsupported DIMM

detected. The

following DIMM

has been

disabled: x

Invalid memory

configuration. The system

will run but with the

specified memory module

disabled.

Ensure that the memory

modules are installed in a valid

configuration. See "General

Memory Module Installation

Guidelines" on page 86.

Unsupported

memory

configuration.

DIMM mismatch

across slots

detected:

x,x,...

Invalid memory

configuration. Memory

modules are mismatched in

the specified slots.

Ensure that the memory

modules are installed in a valid

configuration. See "General

Memory Module Installation

Guidelines" on page 86.

Warning: A fatal

error has caused

system reset!

Please check the

system event log!

A fatal system error

occurred and caused the

system to reboot.

Check the SEL for

information that was logged

during the error. See the

applicable troubleshooting

section in "Troubleshooting

Your System" on page 111 for

any faulty components

specified in the SEL.

Warning: Control

Panel is not

installed.

The control panel is not

installed or has a faulty

cable connection.

Install the control panel, or

check the cable connections

between the display module,

the control panel board, and

the system board. See "Control

Panel Assembly" on page 104.

Warning! No micro

code update

loaded for

processor n.

Micro code update failed.

Update the BIOS firmware.

See "Getting Help" on

page 135.

Message

Causes

Corrective Actions