Dell PowerEdge T110 II User Manual

Page 28

Advertising
background image

28

About Your System

The following

DIMMs should

match

in

geometry:

x,x,...

Invalid memory

configuration. The

specified memory modules

do not match in size,

number of ranks, or

number of data lanes.

Ensure that the memory

modules are installed in a valid

configuration. See "General

Memory Module Installation

Guidelines" on page 86.

The following

DIMMs should

match

in rank

count:

x,x,...

The following

DIMMs should

match in size:

x,x,...

The following

DIMMs should

match

in size

and geometry:

x,x,...

The following

DIMMs should

match

in size

and rank count:

x,x,...

Thermal sensor

not detected on

x.

A memory module without

a thermal sensor is installed

in the specified memory

slot.

Replace the memory module.

See "System Memory" on

page 86.

Time-of-day

clock stopped.

Faulty battery or faulty

chip.

See "Troubleshooting the

System Battery" on page 116.

Time-of-day not

set - please run

SETUP program.

Incorrect Time or Date

settings; faulty system

battery.

Check the Time and Date

settings. See "Using the

System Setup Program and

UEFI Boot Manager" on

page 35. If the problem

persists, replace the system

battery. See "System Battery"

on page 97.

Message

Causes

Corrective Actions