Error Code

Message Information

Action

Check the network cable and network connections.

SEL1508

Message

Member <number> could not join the Chassis Group.

Details

The indicated member CMC is a leader of a different CMC
stacking group.

Action

Check if member CMC is a leader of a different chassis
group.

SEL1510

Message

An authentication error detected for Chassis Group Member
<number>.

Details

Group master CMC could not log into the group member
CMC.

Action

Check the login credentials of CMC.

SEL9900

Message

An unsupported event occurred.

Details

The current software version cannot decode this event. You
may need to review this event using a tool which displays
raw data such as Ipmitool with the -vvv option or Racadm
with the -E option.

Action

Upgrade the management software.

SWC4004

Message

A firmware or software incompatibility detected between
iDRAC in slot <number> and CMC.

Details

FlexAddress is not implemented in one of the versions of
firmware.

Action

Check the firmware versions of iDRAC and CMC. Update
with the latest version.

SWC4006

Message

A firmware or software incompatibility detected between
system BIOS in slot <number> and CMC.

Details

FlexAddress is not implemented in one of the versions of
firmware.

Action

Check the firmware versions of BIOS and CMC. Update with
the latest version.

SWC4008

Message

A firmware or software incompatibility detected between
CMC 1 and CMC 2.

140