Storage controller card – Dell PowerEdge VRTX User Manual

Page 67

Advertising
background image

4. To remove the battery, press down firmly on the positive side of the connector and lift the battery

out of the securing tabs at the negative side of the connector.

5. To install a new system battery:

a) Support the battery connector by pressing down firmly on the positive side of the connector.
b) Hold the battery with the "+" facing up and slide it under the securing tabs at the positive side of

the connector.

6. Press the battery straight down into the connector until it snaps into place.

7. Reinstall the system board.

8. Close the server module.

9. Install the server module in the enclosure.

10. Enter the System Setup to confirm that the battery is operating properly.

11. Enter the correct time and date in the System Setup's Time and Date fields.

12. Exit the System Setup.

13. To test the newly installed battery, remove the server module for at least an hour.

14. After an hour, reinstall the server module.

15. Enter the System Setup and if the time and date are still incorrect, see

Getting Help

.

Figure 24. Replacing the NVRAM Backup Battery

1.

positive side of battery

2. negative side of battery connector

Storage Controller Card

Your system includes dedicated expansion-card slots on the system board for a storage controller card
that provides the integrated storage subsystem for your system’s hard drives/PCIe SSDs. The storage
controller card supports SAS hard drives.

NOTE: The storage controller card is located underneath the drive bays.

NOTE: The storage controller card is installed on the system board connector labeled as MiniPERC
CARD.

67