background image

Error Code

Message Information

3.

If the issue persists, see

Getting Help

.

VLT0207

Message

The memory module <number> <name> voltage is less than
the lower critical threshold.

LCD Message

Memory module <number> <name> voltage is outside of
range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

Action

1.

Review system logs for power supply exceptions.

2.

Re-configure the system to minimum configuration,

inspect and reinstall system cables.

3.

If the issue persists, see

Getting Help

.

VLT0208

Message

The memory module <number> <name> voltage is greater
than the upper warning threshold.

LCD Message

Memory module <number> <name> voltage is outside of
range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

Action

1.

Review system logs for power supply exceptions.

2.

Re-configure the system to minimum configuration,

inspect and reinstall system cables.

3.

If the issue persists, see

Getting Help

.

VLT0209

Message

The memory module <number> <name> voltage is greater
than the upper critical threshold.

LCD Message

Memory module <number> <name> voltage is outside of
range.

Details

System hardware detected an over voltage or under voltage
condition.

If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.

150