Dell PowerEdge R210 User Manual

Page 7

Advertising
background image

SATA port x device error.

Sector not found.

Seek error.

Seek operation failed.

Faulty hard drive or USB medium or device.

Replace the USB medium or device. Ensure that the USB is
properly connected. See

Troubleshooting a USB Device

or

Troubleshooting a Hard Drive

for the appropriate drive(s)

installed in your system.

Shutdown failure.

General system error.

See

Getting Help

.

The amount of system memory has changed.

Memory has been added or removed or a
memory module may be faulty.

If memory has been added or removed, this message is
informative and can be ignored. If memory has not been
added or removed, check the SEL to determine if single-bit or
multi-bit errors were detected and replace the faulty memory
module. See

Troubleshooting System Memory

.

The following DIMMs should match in

geometry: x,x,...

Invalid memory configuration. The specified
memory modules do not match in size,
number of ranks, or number of data lanes.

Ensure that the memory modules are installed in a valid
configuration. See

General Memory Module Installation

Guidelines

.

The following DIMMs should match in rank

count: x,x,...

The following DIMMs should match in size:

x,x,...

The following DIMMs should match in size

and geometry: x,x,...

The following DIMMs should match in size

and rank count: x,x,...

Thermal sensor not detected

on x.

A memory module without a thermal sensor
is installed in the specified memory slot.

Replace the memory module.

System Memory

.

Time-of-day clock stopped.

Faulty battery or faulty chip.

See

Troubleshooting the System Battery

.

Time-of-day not set - please run SETUP

program.

Incorrect Time or Date settings; faulty system
battery.

Check the Time and Date settings. See

Using the System

Setup Program and UEFI Boot Manager

. If the problem

persists, replace the system battery. See

System Battery

.

Timer chip counter 2 failed.

Faulty system board.

See

Getting Help

.

TPM configuration operation honored.

System will now reset.

A Trusted Platform Module (TPM)
configuration command has been entered.
The system will reboot and execute the
command.

Information only.

TPM configuration operation is pending.

Press (I) to Ignore OR (M) to Modify to

allow this change and reset the system.

WARNING: Modifying could prevent

security.

This message displays during system restart
after a TPM configuration command has been
entered. User interaction is required to
proceed.

Enter I or M to proceed.

TPM failure.

A TPM function has failed.

See

Getting Help

.

Unable to launch System Services image.

System halted!

System halted after F10 keystroke because
System Services image is either corrupted in
the system firmware or has been lost due to
system board replacement.

Restart the system and update the USC repository to the
latest software to restore full functionality. See the USC user
documentation for more information.

The iDRAC6 Enterprise card flash memory
may be corrupted.

Restore the flash memory using the latest version on
support.dell.com. See the iDRAC6 user's guide for instructions
on performing a field replacement of the flash memory.

Unexpected interrupt in protected mode.

Improperly seated memory modules or faulty
keyboard/mouse controller chip.

Reseat the memory modules. See

Troubleshooting System

Memory

. If the problem persists, see

Getting Help

.

Unsupported CPU combination.

Unsupported CPU stepping detected.

Processor is not supported by the system.

Install a supported processor. See

Processor

.

Unsupported DIMM detected. The following

DIMM has been disabled: x

Invalid memory configuration. The system will
run but with the specified memory module
disabled.

Ensure that the memory modules are installed in a valid
configuration. See

General Memory Module Installation

Guidelines

.

Unsupported memory configuration. DIMM

mismatch across slots detected: x,x,...

Invalid memory configuration. Memory
modules are mismatched in the specified
slots.

Ensure that the memory modules are installed in a valid
configuration. See

General Memory Module Installation

Guidelines

.

Warning: A fatal error has caused system

reset! Please check the system event log!

A fatal system error occurred and caused the
system to reboot.

Check the SEL for information that was logged during the
error. See the applicable troubleshooting section in

Troubleshooting Your System

for any faulty components

specified in the SEL.

Warning: Control Panel is not installed.

The control panel is not installed or has a
faulty cable connection.

Install the control panel, or check the cable connections
between the display module, the control panel board, and the
system board. See

Control Panel Assembly

.

Warning! No micro code update loaded for

processor n.

Micro code update failed.

Update the BIOS firmware. See

Getting Help

.

Warning! Performance degraded. CPU and

memory set to minimum frequencies to meet

PSU wattage. System will reboot.

The system configuration of processor,
memory modules, and expansion card may
not be supported by the power supplies.

If any system components were just upgraded, return the
system to the previous configuration. If the system boots
without this warning, then the replaced component(s) are not
supported with this power supply. See

Power Supply

.

Warning! Unsupported memory configuration

detected. The memory configuration is not

optimal. The recommended memory

configuration is: <message>

Invalid memory configuration. The system will
run but with reduced functionality.

Ensure that the memory modules are installed in a valid
configuration. See

General Memory Module Installation

Guidelines

. If the problem persists, see

Troubleshooting

System Memory

.

Advertising