Table 1-3 lists the drive indicator patterns for RAID hard drives. Different
patterns are displayed as drive events occur in the system. For example, if a
hard drive fails, the "drive failed" pattern appears. After the drive is selected
for removal, the "drive being prepared for removal" pattern appears, followed
by the "drive ready for insertion or removal" pattern. After the replacement
drive is installed, the "drive being prepared for operation" pattern appears,
followed by the "drive online" pattern.

NOTE:

For non-RAID configurations, only the drive-activity indicator is active. The

drive-status indicator is off.

Table 1-3.

Hard-Drive Indicator Patterns for RAID

Condition

Drive-Status Indicator Pattern

Identify drive/preparing for
removal

Blinks green two times per second

Drive ready for insertion or
removal

Off

Drive predicted failure

Blinks green, amber, and off.

Drive failed

Blinks amber four times per second.

Drive rebuilding

Blinks green slowly.

Drive online

Steady green.

Rebuild aborted

Blinks green three seconds, amber three seconds, and
off six seconds.

book.book Page 18 Sunday, June 21, 2009 5:16 PM