About Your System

Memory address line

failure at

address,

read

value

expecting

value

Memory double word

logic failure at

address, read value

expecting

value

Memory odd/even

logic failure at

address, read value

expecting

value

Memory write/read

failure at

address,

read

value

expecting

value

Faulty or improperly
installed memory
modules.

See "Troubleshooting System
Memory" on page 137.

Memory tests

terminated by

keystroke

POST memory test
terminated by pressing
the spacebar.

Information only.

No boot device

available

Faulty or missing optical
drive subsystem, hard
drive, or hard-drive
subsystem, or no bootable
USB key installed.

Use a bootable USB key, CD,
or hard drive. If the problem
persists, see
"Troubleshooting an Internal
USB Key" on page 139 and
"Troubleshooting a Hard
Drive" on page 144. See
"Entering the System Setup
Program" on page 47 for
information on setting the
order of boot devices.

Table 1-7.

System Messages (continued)

Message

Causes