Dell POWEREDGE 300 User Manual

Page 30

Advertising
background image

30

About Your System

E1A15

SAS Cable C

SAS cable C is missing or
bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help" on
page 167.

E1A18

PDB Ctrl

Cable

Control cable for the power
distribution board (PDB) is
missing or bad

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help" on
page 167.

E2010

No Memory

No memory is installed in
the system.

Install memory. See
"Installing Memory
Modules" on page 105.

E2011

Mem Config

Err

Memory detected, but is not
configurable. Error detected
during memory
configuration.

See "Troubleshooting
System Memory" on
page 137.

E2012

Unusable

Memory

Memory is configured, but
not usable. Memory
subsystem failure.

See "Troubleshooting
System Memory" on
page 137.

E2013

Shadow BIOS

Fail

The system BIOS failed to
copy its flash image into
memory.

See "Troubleshooting
System Memory" on
page 137.

E2014

CMOS Fail

CMOS failure. CMOS RAM
not functioning properly.

See "Getting Help" on
page 167.

E2015

DMA

Controller

DMA controller failure.

See "Getting Help" on
page 167.

E2016

Int

Controller

Interrupt controller failure.

See "Getting Help" on
page 167.

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on
page 167.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

book.book Page 30 Sunday, June 21, 2009 5:16 PM