About Your System

19

E1414

CPU # Thermtrip

Specified microprocessor is out of
acceptable temperature range and
has halted operation.

See "Troubleshooting System
Cooling Problems" on page 105.
If the problem persists, ensure
that the microprocessor heat
sinks are properly installed. See
"Troubleshooting the
Microprocessors" on page 114.

NOTE:

The LCD continues to

display this message until the
system’s power cord is
disconnected and reconnected to
the AC power source, or the SEL is
cleared using either Server
Assistant or the BMC Management
Utility. See the Dell OpenManage
Baseboard Management
Controller User’s Guide

for

information about these utilities.

E1418

CPU # Presence

Specified processor is missing or
bad, and the system is in an
unsupported configuration.

See "Troubleshooting the
Microprocessors" on page 114.

E1423

CPU # VRM

Missing

VRM for specified processor is
missing or faulty.

Remove and reseat the specified
VRM. See "Processor VRMs" on
page 66.

If the problem persists, the
system board is faulty. See
"Getting Help" on page 129.

E141C

CPU Mismatch

Processors are in a configuration
unsupported by Dell.

Ensure that your processors
match and conform to the type
described in the Microprocessor
Technical Specifications outlined
in your system’s Getting Started
Guide.

E141F

CPU Protocol

The system BIOS has reported a
processor protocol error.

See "Getting Help" on page 129.

E1420

CPU Bus PERR

The system BIOS has reported a
processor bus parity error.

See "Getting Help" on page 129.

E1421

CPU Init

The system BIOS has reported a
processor initialization error.

See "Getting Help" on page 129.

Table 1-7.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions

Advertising