Replacing a cooling fan, Cooling shrouds, Removing the cooling shrouds – Dell PowerEdge 6950 User Manual

Page 49

Advertising
background image

Installing System Components

49

Replacing a Cooling Fan

NOTE:

The procedure for installing each individual fan is the same.

1 Ensure that the fan handle is upright and lower the fan into its retention base until the fan is fully

seated. Then lower the fan handle until it snaps into place. See Figure 3-4.

2 Close the system. See "Closing the System" on page 47.

Cooling Shrouds

The three cooling shrouds direct airflow within the system.

Removing the Cooling Shrouds

NOTICE:

Do not remove the cooling shrouds if the system is turned on. The cooling shrouds must be installed to

direct the airflow from the fans.

1 First, remove the top cooling shroud by using the finger holes to lift the shroud straight up from the

system. See Figure 3-5.

2 Remove the left and right cooling shrouds as necessary to access the interior of the system.