Dell PowerEdge 6950 User Manual

Page 22

Advertising
background image

22

About Your System

E2013

Shadow BIOS Fail

The system BIOS failed to copy
its flash image into memory.

See "Troubleshooting System
Memory" on page 106.

E2014

CMOS Fail

CMOS failure. CMOS RAM not
functioning properly.

See "Getting Help" on page 129.

E2015

DMA Controller

DMA controller failure.

See "Getting Help" on page 129.

E2016

Int Controller

Interrupt controller failure.

See "Getting Help" on page 129.

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on page 129.

E2018

Prog Timer

Programmable interval timer
error.

See "Getting Help" on page 129.

E2019

Parity Error

Parity error.

See "Getting Help" on page 129.

E201A

SIO Err

SIO failure.

See "Getting Help" on page 129.

E201B

Kybd Controller

Keyboard controller failure.

See "Getting Help" on page 129.

E201C

SMI Init

System management interrupt
(SMI) initialization failure.

See "Getting Help" on page 129.

E201D

Shutdown Test

BIOS shutdown test failure.

See "Getting Help" on page 129.

E201E

POST Mem Test

BIOS POST memory test failure. See "Troubleshooting System

Memory" on page 106. If problem
persists, see "Getting Help" on
page 129.

E201F

DRAC Config

Dell remote access controller
(DRAC) configuration failure.

Check screen for specific error
messages.

Ensure that the DRAC card and
cables are properly seated. See
"RAC Card" on page 56. If
problem persists, see your DRAC
documentation.

E2020

CPU Config

CPU configuration failure.

Check screen for specific error
messages.

E2021

Memory

Population

Incorrect memory configuration.
Memory population order
incorrect.

Check screen for specific error
messages. See "Troubleshooting
System Memory" on page 106.

E2022

POST Fail

General failure after video.

Check screen for specific error
messages.

Table 1-7.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions