Dell OptiPlex 3010 (Mid 2012) User Manual

Page 61

Advertising
background image

Controls and Lights

NOTE: You can test the health of the power
system by pressing the test button. When
the system power supply voltage is within
specification, the self-test LED lights up. If
the LED does not light up, the power supply
may be defective. AC power must be
connected during this test.

Power

Wattage

Maximum Heat

Dissipation

Voltage

Mini-Tower

265 W

1390 BTU/hr

100 VAC to 240 VAC, 50 Hz to 60 Hz, 5.0 A

Desktop

250 W

1312 BTU/hr

100 VAC to 240 VAC, 50 Hz to 60 Hz, 4.4 A

Small Form Factor

240 W

1259 BTU/hr

100 VAC to 240 VAC, 50 Hz to 60 Hz, 3.6 A;

Coin-cell battery

3 V CR2032 lithium coin cell

NOTE: Heat dissipation is calculated by using the power supply wattage rating.

Physical

Height

Width

Depth

Weight

Mini-Tower

36.00 cm (14.17
inches)

17.50 cm (6.89 inches) 41.70 cm (16.42

inches)

8.87 kg (19.55 lb)

Desktop

36.00 cm (14.17
inches)

10.20 cm (4.01 inches) 41.00 cm (16.14

inches)

7.56 kg (16.67 lb)

Small Form Factor

29.00 cm (11.42
inches)

9.26 cm (3.65 inches)

31.20 cm (12.28
inches)

5.70 kg (12.57 lb)

Environmental

Temperature range:

Operating

10 °C to 35 °C (50 °F to 95 °F)

Storage

–40 °C to 65 °C (–40 °F to 149 °F)

Relative humidity (maximum):

Operating

20% to 80% (non-condensing)

Storage

5% to 95% (non-condensing)

Maximum vibration:

Operating

0.26 GRMS

Storage

2.2 GRMS

Maximum shock:

Operating

40 G

Storage

105 G

61