Uninterruptible power supply (ups) – Dell PowerVault 735N (Rackmount NAS Appliance) User Manual

Page 78

Advertising
background image

7-18

System Administrator’s Guide

10. If you plan long-term coexistence between Active Directory and NetWare, you

are now finished, unless you want to migrate a subset of users, computers, and/
or files. If you plan to continue by migrating in stages from NetWare to Active
Directory, do the following in the time-frame that is convenient for you:

Install and configure File and Print Services for Netware (to let NetWare cli-
ents access files and printers on Windows 2000 servers) and Gateway
Services for NetWare (to let Windows clients access files and printers on
NetWare servers).

Replace services or applications that require NDS with commensurate soft-
ware compatible with Active Directory. Do large conversions (such as
GroupWise to Exchange) as separate projects.

Migrate the pilot group of users and their files (adapt instructions from the
migration steps provided in the “Small Environment”section). Get the pilot
group’s feedback, and then set a schedule to migrate additional groups of
users, according to the priorities you have established.

Migrate the rest of the users as appropriate (for example, if you migrate the
set of applications they use, it is time to migrate them as well).

For further information see the Novell Web site, http://support.novell.com/servlet/
Knowledgebase
and the Microsoft Windows 2000 Web site,
http://www.microsoft.com/windows2000.

Uninterruptible Power Supply (UPS)

When you are in Terminal Services Advanced Client, you can control the settings for
your UPS. In Power Options on the Control Panel, the operating system includes
default settings for an American Power Conversion Uninterruptible Power Supply.

The default settings are:

1.

Enable all notifications.

Seconds between power failure and first notification: 5

Seconds between subsequent power failure notifications: 120

2.

Shut down when the UPS battery is almost exhausted.

3.

Turn off the UPS.

If you are using a UPS and want to change these settings, you need to connect a key-
board, mouse, and monitor to the system. See Microsoft Windows 2000 Help for
more information.

The system is configured to accept a serial connection from the UPS in serial port 2,
called the UPS port in the

Dell PowerVault 735N Systems Installation and Trouble-

shooting Guide

.

See the documentation for your UPS for more information on how to use it.