Failback policy, Failback policy configurations in access gateway, Failback example – Dell POWEREDGE M1000E User Manual

Page 75

Advertising
background image

Access Gateway Administrator’s Guide

55

53-1002743-01

Failback policy

3

3. Enter the ag

--

failoverdisable -pg pgid command to disable failover.

switch:admin> ag --failoverdisable -pg 3

Failover policy is disabled for port group 3

Upgrade and downgrade considerations for the Failover policy

Consider the following when upgrading or downgrading Fabric OS versions:

•

Downgrading to Fabric OS v6.4.0 or earlier is supported.

•

Upgrading from Fabric OS v6.4.0 to v7.1.0 or downgrading from Fabric OS v7.1.0 to v6.4.0 will
not change failover settings.

Failback policy

The Failback policy provides a means for hosts that have failed over to automatically reroute back
to their intended mapped N_Ports when these N_Ports come back online. The Failback policy is an
attribute of an N_Port and is enabled by default when a port is locked to the N_Port.

Only the originally mapped F_Ports fail back. In the case of multiple N_Port failures, only F_Ports
that were mapped to a recovered N_Port experience failback. The remaining F_Ports are not
redistributed.

NOTE

For port mapping, the Failback policy must be enabled on an N_Port for failback to occur. For device
mapping, the Failback policy has no effect. If a device is mapped to a port group, it will always fail
over to an online N_Port in the port group (or secondary N_Port if configured) and will remain
connected to this failover N_Port when the original N_Port comes back online.

NOTE

If failover and failback policy are disabled, an F_Port mapped to an N_Port will go offline when the
N_Port goes offline and it will go online when the N_Port comes online.

Failback policy configurations in Access Gateway

The following sequence describes how a failback event occurs:

•

When an N_Port comes back online, with the Failback policy enabled, the F_Ports that were
originally mapped to it are temporarily disabled.

•

The F_Port is rerouted to the primary mapped N_Port, and then re-enabled.

•

The host establishes a new connection with the fabric.

NOTE

The failback period is quite fast and rarely causes an I/O error at the application level.

Failback example

In Example 3, described in

Figure 12

on page 56, the Access Gateway N_1 remains disabled

because the corresponding F_A1 port is offline. However, N_2 comes back online. See

Figure 11

on page 52 for the original failover scenario.