Figure 12, Failback – Dell POWEREDGE M1000E User Manual

Page 76

Advertising
background image

56

Access Gateway Administrator’s Guide

53-1002743-01

Failback policy

3

Ports F_1 and F_2 are mapped to N_1 and continue routing to N_3. Ports F_3 and F_4, which were
originally mapped to N_2, are disabled and rerouted to N_2, and then enabled.

FIGURE 12

Failback behavior

Enabling and disabling the Failback policy on an N_Port

Use the following steps to enable or disable the Failback policy on N_Ports.

1. Connect to the switch and log in using an account assigned to the admin role.

2. Enter the ag

--

failbackshow n_portnumber command to display the failback setting.

switch:admin> ag --failbackshow 13

Failback on N_Port 13 is not supported

3. Use the following commands to enable or disable the Failback policy:

Enter the ag

--

failbackenable n_portnumber command to enable failback.

switch:admin> ag --failbackenable 13

Failback policy is enabled for port 13

Enter the ag --failbackdisable n_portnumber command to disable failback.

switch:admin> ag --failbackdisable 13

Failback policy is disabled for port 13

F_A2

Hosts

Access Gateway

Edge Switch

Fabric

(Switch_A)

F_4

F_3

F_2

F_1

N_1

F_A1

N_3

F_B1

Host_1

Host_2

Host_3

Host_4

F_5

Host_5

F_6

Host_6

F_7

Host_7

F_8

Host_8

Edge Switch

(Switch_B)

N_4

F_B2

N_2

Legend

Physical connection
Mapped online
Failover route online
Original mapped route
(offline)

Example 3

Advertising