Powerconnect 5316m ethernet, Switch module, Fibre channel pass-through module – Dell POWEREDGE 1855 User Manual

Page 23: Powerconnect 5316m ethernet switch module

Advertising
background image

 

PowerConnect 5316M Ethernet Switch Module

The PowerConnect 5316M Ethernet switch module is a 16-port switch with 6 uplinks and 10 downlinks (see 

Figure 2

-12

). The uplinks connect to the external

Ethernet network and operate at 10/100/1000 Mb. The downlinks connect to the embedded Ethernet controller on the server module and operate at 1000 Mb
only.

The PowerConnect 5316M Ethernet switch module is hot-pluggable. To provide connectivity into separate Ethernet networks, two switch modules can be
installed in bays I/O 1 and I/O 2 (see

Figure 2

-5

). I/O bays 3 and 4 require that you install a Gb Ethernet daughter card in the server module. If redundancy is

not required, the switch module must be installed in I/O 1 bay. The switch module has an internal serial port that communicates with the DRAC/MC module.

Table 2

-11

lists the indicators on each switch module. For additional information about the PowerConnect 5316M Ethernet switch module, see the

documentation that shipped with the module.

 

Figure 2-12. PowerConnect 5316M Ethernet Switch Module Indicators and Features

 

Table 2-11. PowerConnect 5316M Ethernet Switch Module Indicators 

 

Fibre Channel Pass-Through Module

The Fibre Channel pass-through module provides a bypass connection between the Fibre Channel daughter card in the server module and optical transceivers
for direct connection into a Fibre Channel switch or a storage array. (see

Figure 2

-13

). The Fibre Channel pass-through modules are hot-pluggable. The Fibre

Channel pass-through module in I/O bay 3 connects to port 1 on the optional Fibre Channel daughter card installed in a server module. The Fibre Channel
pass-through module in I/O bay 4 connects to port 2 on the optional Fibre Channel daughter card installed in a server module. To provide redundancy, both
I/O bay 3 and I/O bay 4 must have Fibre Channel pass-through modules installed.

Table 2

-12

lists the functionality of the Fibre Channel pass-through module

indicators. For additional information on installing this module, see "

Chassis I/O Module

" in "Installing System Options."

 

Figure 2-13. Fibre Channel Pass-through Module Indicators and Features

 

Indicator Type

 

Activity
Indicator

 

Indicator Code

Speed/link activity indicator
(bicolor)

 

 

 

 

Off

Not connected.

Green

The port is connected to a valid link partner on the network.

Green
blinking

Network data is being sent or received at 1 Gb.

Amber

The port is connected to a valid link partner on the network.

Amber
blinking

Network data is being sent or received at 10 Mb or 100 Mb.

Duplex mode indicator

Green

The port is operating at full duplex mode.

Off

The port is operating at half duplex mode.

System/diagnostic indicator

Green
blinking

Module is being powered down by the DRAC/MC controller due to an I/O module mismatch. See "

Guidelines

for Installing Connectivity Modules

."

Off

Module is operating normally.

NOTE:

The Fibre Channel pass-through module includes Short Wave Small Form Factor Pluggable (SFP) optical transceivers. To ensure proper

functionality, use only the SFPs provided with this module.

Advertising