Troubleshooting the server module board, Troubleshooting the server module battery – Dell POWEREDGE 1855 User Manual

Page 44

Advertising
background image

 

3.

Ensure that the microprocessor(s) and heat sink(s) are properly installed. See "

Microprocessors

" in "Installing System Options."

If your system only has one microprocessor installed, ensure that it is installed in socket PROC_1. See

Figure A

-3

.

 

4.

Close the server module. See "

Closing the Server Module

" in "Installing System Options."


 

5.

Install the server module. See "

Installing a Server Module

" in "Installing System Options."


 

6.

Run Quick Tests in the system diagnostics. See "

Running System Diagnostics

."

If the tests fail or the problem persists, see "

Getting Help

."

 

Troubleshooting the Server Module Board

 

Problem

l

 

System message indicates a problem with the server module board

 

Action

 

 

1.

Turn off the server module.

 

2.

Remove and reinstall the server module. See "

Server Modules

" in "Installing System Options."


 

3.

Turn on the server module.

 

4.

Run the system board test in the system diagnostics. See "

Running System Diagnostics

."

If the tests fail, see "

Getting Help

."

 

Troubleshooting the Server Module Battery

 

Problem

l

 

System message indicates a problem with the battery

l

 

System Setup program loses system configuration information

l

 

System date and time do not stay current

Each server module contains a battery, which maintains the server module configuration, date, and time information in NVRAM when you turn off the server
module. You may need to replace the battery if an incorrect time or date is displayed during the boot routine.

You can operate the server module without a battery; however, the server module configuration information maintained by the battery in NVRAM is erased
each time you remove power from the server module. Therefore, you must re-enter the system configuration information and reset the options each time the
server module boots until you replace the battery.

 

Action

 

 

1.

Re-enter the time and date through the System Setup program. See "Using the System Setup Program" in your User's Guide.

 

2.

Remove the server module for at least one hour. See "

Removing a Server Module

" in "Installing System Options."


 

3.

Install the server module. See "

Installing a Server Module

" in "Installing System Options."


 

CAUTION:

Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See

your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against
electrostatic discharge.

CAUTION:

Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as