Server module messages, Table 2 – Dell POWEREDGE 1855 User Manual

Page 25

Advertising
background image

 

Table 2-13. Gb Pass-through Module Indicators

 

Server Module Messages

System messages appear on the screen to notify you of a possible problem with the system.

Table 2

-14

lists the system messages that can occur and the

probable cause and corrective action for each message.

 

 

Table 2-14. Server Module Messages 

NOTE:

Connectors on the Gb pass-through module correspond directly to the server module number. For example, server module 5 is connected to port

5 on the Gb pass-through module.

 

Indicator Type

 

Activity
Indicator

 

Indicator Code

Link indicator/activity
indicator

 

 

 

Green/amber
blinking

The Gb Ethernet connector is linked to the server module and there is network activity

Green/off

The Gb Ethernet connector is linked to the server module and there is no network activity.

Off/amber blinking The Gb Ethernet connector is not linked to the server module and there is network activity.

Off/off

The Gb Ethernet connector is not linked to the server module and there is no network activity.

Status indicator

 

Green

Module is operating correctly.

Green blinking

Module is being powered down by the DRAC/MC controller due to an I/O module mismatch. See "

Guidelines

for Installing Connectivity Modules

."

CAUTION:

Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as

authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE:

If you receive a system message that is not listed in

Table 2

-14

, check the documentation for the application that is running when the message

appears or the operating system's documentation for an explanation of the message and recommended action.

 

Message

 

Causes

 

Corrective Actions

Amount of available memory limited to

256MB!

OS Install Mode is enabled
in the System Setup
program.

Disable OS Install Mode in the System Setup program. See "Using the
System Setup Program" in your User's Guide.

Attempting to update Remote Configuration.

Please wait....

Remote Configuration is in
progress.

Wait until the process is complete.

BIOS Update Attempt Failed

BIOS remote update failed.

Retry update.

Caution! NVRAM_CLR jumper is installed on

system board.

NVRAM_CLR switch is set to
"on."

Set the NVRAM_CLR switch to "off." See

Figure A

-2

for the jumper location.

CD-ROM drive not found

Improperly connected or
missing CD drive.

If no custom cable is installed, disable the IDE controller. See "Using the
System Setup Program" in the User's Guide.

If an optical drive is installed, see "

Troubleshooting USB Devices

" in

"Troubleshooting Your System."

CPUs with different cache sizes detected.

Mismatched processors are
installed.

Install a correct version of the microprocessor so that both microprocessors
have the same cache size. See "

Microprocessors

" in "Installing System

Options."