Decreasing available memory

Faulty or improperly installed
memory modules.

Ensure that all memory modules are properly installed. See "

Troubleshooting

Server Module Memory

" in "Troubleshooting Your System."

Diskette drive 0 seek failure

Incorrect configuration
settings in System Setup
program.

Run the System Setup program to correct the settings. See "Using the System
Setup Program" in your User's Guide.

Faulty or improperly installed
diskette or optical drive to
the custom cable.

Replace the diskette. Ensure that the diskette drive and optical drive cables
are properly connected. See "

Troubleshooting USB Devices

" in

"Troubleshooting Your System."

Diskette read failure

Faulty or improperly inserted
diskette.

Replace the diskette.

Diskette subsystem reset failed

Faulty diskette drive or
optical drive controller.

Ensure that the diskette drive and optical drive cables are properly connected
to the custom cable. See "

Troubleshooting USB Devices

" in "Troubleshooting

Your System." If the problem persists, see "

Getting Help

."

Drive not ready

Diskette missing or
improperly inserted in
diskette drive.

Reinsert or replace the diskette.

Error: Incorrect memory configuration.

Ensure memory in slots DIMM1_A and

DIMM1_B, DIMM2_A and DIMM2_B, DIMM3_A and

DIMM3_B match identically in size, speed,

and rank.

One or more unmatched
pairs of memory modules are
detected.

Ensure that the memory modules are installed in matched pairs. See "

General

Memory Module Installation Guidelines

" in "Installing System Options."

Error: Incorrect memory configuration.

Memory slots DIMM3_A and DIMM3_B only

support single rank DIMMs. Remove the dual

rank DIMMs from slots DIMM3_A and DIMM3_B.

Dual-rank memory modules
are installed in slots
DIMM3_A and DIMM3_B.

Ensure that only single-rank memory modules are installed in slots DIMM3_A
and DIMM3_B. See "

General Memory Module Installation Guidelines

" in

"Installing System Options."

Error: Incorrect memory configuration.

Move DIMM3_A and DIMM3_B into DIMM2_A and

DIMM2_B.

Memory modules are not
installed in consecutive
banks.

Move memory modules from slots DIMM3_A and DIMM3_B into DIMM2_A and
DIMM2_B. See "

General Memory Module Installation Guidelines

" in "Installing

System Options."

Error: Incorrect memory configuration.

Swap the DIMMs in slots DIMM1_A and

DIMM1_B with DIMMs in slots DIMM2_A and

DIMM2_B.

If dual-rank memory
modules are installed in the
system, they must be
installed in slots DIMM1_A
and DIMM1_B.

Swap memory modules in slots DIMM2_A and DIMM2_B with modules in
DIMM1_A and DIMM1_B. See "

General Memory Module Installation Guidelines

"

in "Installing System Options."

 

Error: Incorrect memory configuration.

Memory slots DIMM3_A and DIMM3_B must be

empty if dual rank memory DIMMS are in

slots DIMM2_A and DIMM2_B.

Memory modules are
installed in bank 3. Dual

-

rank memory modules are
installed in banks 1 and 2.

Remove memory modules from slots DIMM3_A and DIMM3_B. See "

General

Memory Module Installation Guidelines

" in "Installing System Options."

 

Error 8602: Auxiliary device failure.

Verify that the keyboard and mouse are

securely attached to correct connectors.

Loose or improperly
connected mouse or
keyboard cable to the
custom cable; faulty mouse
or keyboard.

Replace the mouse. If the problem persists, replace the keyboard.

Gate A20 failure

Faulty keyboard controller
(faulty server module
board).

See "

Getting Help

."

General failure

Operating system corrupted
or improperly installed.

Reinstall the operating system.

Keyboard controller failure

Faulty keyboard controller
(faulty server module
board).

See "

Getting Help

"

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Loose or improperly
connected keyboard cable;
faulty keyboard to the
custom cable; faulty
keyboard controller.

Ensure that the keyboard is properly connected. If the problem persists,
replace the keyboard. If the problem persists, see "

Getting Help

."

 

Keyboard fuse has failed.

Keyboard fuse has failed.

Replace the keyboard.

Manufacturing mode detected

System is incorrectly
configured.

After the message appears during system module boot, press <Alt><F> to
turn off manufacturing mode.

Memory address line failure at address,

read value expecting value

Memory double word logic failure at

address, read value expecting value

Memory odd/even logic failure at start

address to end address

Memory write/read failure at address, read

value expecting value

Faulty or improperly installed
memory modules, or faulty
server module board.

Ensure that all memory modules are properly installed. See "

Troubleshooting

Server Module Memory

" in "Troubleshooting Your System." If the problem

persists, see "

Getting Help

."

Memory tests terminated by keystroke

The spacebar was pressed
during POST to terminate
the memory test.

Information only.

No boot device available

Faulty or missing diskette
drive, optical drive, or hard
drive.

 

Check the Integrated Devices configuration settings in the System Setup
program. See "Using the System Setup Program" in your User's Guide. Ensure
that either SCSI Controller, Diskette Controller, or IDE CD-ROM Controller
is enabled. If the server module is booting from a SCSI controller, ensure that
the controller is properly connected. If the problem persists, replace the drive.
See "

Hard Drives

."

No boot sector on hard-disk drive

An operating system is not
on the hard drive.

Check the hard-drive configuration settings in the System Setup program. See
"Using the System Setup Program" in your User's Guide.