Hardware Installation

29

Installing the PERC H200 Modular Card

NOTE:

For more information on removing and installing blade system parts,

see your system’s Hardware Owner’s Manual or the User’s Guide from the
Dell Support website at support.dell.com.

The storage controller card is located below the hard drive bays of the
Dell Blade system.

To remove the storage controller card:

1 Remove the Dell Blade system from the Blade system chassis.
2 Remove the system cover of the Blade system.
3 Remove the system board and place it on a stable and flat surface.
4 Open the release lever to disconnect the storage controller card edge

connector from the system board connector as illustrated in Figure 4-4.

5 Lift the storage controller card straight up from the system board as illustrated

in Figure 4-4.

Figure 4-4.

Removing and Installing the Storage Controller Card

1

storage controller card

2

release lever

1

2

PERC H200.book Page 29 Tuesday, July 13, 2010 4:15 PM